Plug-in Hand Rehabilitation Training Device Exporter

Unit 301 No. 6 Xianghong Road,Torch Hi-Tech Zone Industrial Park,Xiang'an District, Xiamen P.R.China
+86-13365922007 [email protected]

Plug-in Hand Rehabilitation & Physical Therapy Device

FDA & CE Certified Pneumatic Hand Rehab System | 100–240V Continuous Operation, Active Mirror Therapy, Adjustable Grip/Release Interval Control & Task-Oriented Training for Stroke, Hemiplegia & Brain Injury Recovery

View Compliance Docs
Overview
The SL-FR02 is a plug-in hand rehabilitation and physical therapy device designed for patients suffering from upper-limb motor dysfunction caused by stroke, cerebral hemorrhage, hemiplegia, traumatic brain injury, nerve injury, post-operative stiffness, and long-term immobilization. As part of the modern hand robot gloves category, it combines soft pneumatic actuation, ergonomic glove design, and neuro-rehabilitation principles to support safe, repetitive, and task-oriented finger movement training.
Plug-in Hand Rehabilitation & Physical Therapy Device
Unlike battery-operated recovery products, the SL-FR02 is powered by a 100–240V universal AC input, allowing stable continuous operation in clinics, rehabilitation centers, nursing facilities, and home-care environments. Positioned as professional electric hand rehabilitation robot gloves, the device uses pneumatic bionic muscles to drive natural finger flexion and extension, helping patients perform rhythmic passive and assisted movement without relying on strong voluntary muscle control.
Plug-in Hand Rehabilitation & Physical Therapy Device
The system is more than a simple finger recovery robot machine. It works through three rehabilitation pathways: peripheral sensory stimulation, cerebral motor cortex activation, and skeletal muscle movement assistance. By repeatedly opening and closing the affected hand, the device helps reduce high muscle tone, relieve flexor spasticity, improve local microcirculation, decrease hand edema, maintain joint flexibility, and prevent disuse muscle atrophy. For daily use, the finger rehab gloves guide the hand through gentle and controlled movement patterns that can be adjusted according to the patient’s condition. It is especially suitable for stroke survivors, hemiplegia patients, elderly users with reduced hand function, and patients requiring long-term functional recovery. For hospitals, clinics, rehabilitation departments, and distributors seeking hemiplegia finger rehabilitation trainer robot gloves, the SL-FR02 offers a cost-effective, compliant, and easy-to-operate solution.
Plug-in Hand Rehabilitation & Physical Therapy Device

Clinical Applications & Therapeutic Benefits

Post-Stroke Pathway Activation & Paresis Motor Recovery

After stroke or cerebral hemorrhage, many patients experience weak grip, poor finger extension, reduced coordination, and impaired voluntary control. As electric hand rehabilitation robot gloves, the SL-FR02 delivers repetitive passive flexion and extension to provide continuous sensory feedback to the nervous system. This stimulation helps awaken dormant neural pathways, improve neuromuscular response, and support the rebuilding of hand motor control during early and middle-stage rehabilitation.

Autonomous Mirror Therapy for Central Brain Reorganization

The optional mirror training glove allows the healthy hand to guide synchronized movement on the affected side. The hemiplegia finger rehabilitation trainer robot gloves support mirror therapy by helping the brain observe and reproduce correct movement patterns. This bilateral training method can encourage motor cortex reorganization, strengthen brain-hand coordination, and improve the patient’s ability to relearn independent hand movement.

Hypertonia Management & Spasticity Reduction

Patients with hemiplegia often experience clenched fingers, high flexor tone, limited extension, and painful stiffness. The adjustable grip and release interval allows therapists or caregivers to set training rhythm from 1 to 10 seconds according to muscle tension. The finger rehab gloves provide gentle stretching and repeated opening movement, helping reduce spasticity without sudden pulling or overstimulation.

Edema Reduction & Microcirculation Promotion

The pneumatic motion applies rhythmic compression and release to the fingers and palm. Working as a gentle finger recovery robot machine, the system supports venous return and lymphatic drainage, helping reduce swelling, fluid retention, and localized tissue inflammation. This is useful for patients with post-operative hand swelling, immobilization-related edema, or poor peripheral circulation.

Atrophy Prevention & Continuous Passive Motion

Long periods of hand inactivity can lead to joint stiffness, tendon adhesion, muscle shortening, and progressive loss of function. The hand robot gloves help maintain muscle elasticity and joint capsule flexibility by providing controlled continuous passive motion. Regular training can slow down disuse muscle atrophy, reduce contracture risk, and preserve the foundation for later active rehabilitation.

Task-Oriented Functional Daily Training

Rehabilitation is most effective when movement connects with real-life activities. These electric hand rehabilitation robot gloves allow patients to practice practical tasks such as grasping a bottle, holding a cup, gripping a towel, or touching daily objects. Training sessions of about 20 minutes can help reinforce neuro-motor memory and improve confidence in daily living activities.
Post-Stroke Pathway Activation & Paresis Motor Recovery
Autonomous Mirror Therapy for Central Brain Reorganization
Hypertonia Management & Spasticity Reduction
Edema Reduction & Microcirculation Promotion
Atrophy Prevention & Continuous Passive Motion
Task-Oriented Functional Daily Training
01/06

Specifications

Parameter

Specification

Model

SL-FR02

Device Classification

Plug-in Hand Rehabilitation Device

Certification & Compliance

CE Marked, FDA Cleared

Power Supply

100–240V AC, 50/60Hz (Universal Plug-in Power)

Power Consumption

15W Energy-Efficient Design

Drive Technology

Pneumatic Bionic Muscle (Soft Robotics)

Program Modes

1 Integrated Recovery Program (Fixed Cycle Mode)

Grip/Release Interval

1–10 seconds (Individually Adjustable Control Knob)

Treatment Session Timer

0–30 minutes or Continuous Run Mode

Device Dimensions

30.1 × 23.8 × 12.36 cm

Target Population

Stroke, Hemiplegia, Brain Injury, Paresis & Muscle Stiffness

Cuff System & Customization Options

Standard Accessories & Ergonomic Glove Assembly

Standard Accessories & Ergonomic Glove Assembly

The standard kit includes one main host control unit, one pneumatic bionic recovery glove, and one sensory mirror training glove. An optional air pressure massage glove can also be provided for pre-training relaxation and comfort preparation. The hand robot gloves are made from breathable, skin-friendly, and durable materials suitable for repeated daily use in clinics or home rehabilitation environments.
B2B Procurement Flexibility & OEM/ODM Support

B2B Procurement Flexibility & OEM/ODM Support

To support global distributors, rehabilitation clinics, hospitals, and therapy equipment suppliers, standard inventory can be ordered from 1 unit for clinical testing, market sampling, or patient demonstration. For distributors, electric hand rehabilitation robot gloves can be customized through OEM/ODM services from bulk production quantities, including logo branding, housing color, glove size configuration, localized packaging, manual translation, and regional labeling requirements.

Safety, Operational Reliability & Maintenance

Regulatory Approvals & Global Compliance

Regulatory Approvals & Global Compliance

The SL-FR02 is supported with CE and FDA certification documentation, helping international buyers simplify procurement, import clearance, and compliance review. As a professional finger recovery robot machine, it can support medical distributors, rehabilitation centers, and healthcare institutions that require reliable documentation for regulated markets.
Continuous-Duty Plug-in Engineering

Continuous-Duty Plug-in Engineering

The device uses a stable 100–240V power module and low-power pneumatic pump system. Compared with battery-dependent devices, plug-in operation avoids battery aging, charging interruptions, and capacity degradation. This makes it suitable for high-frequency therapy rooms, multi-patient clinical use, and long-term home rehabilitation plans.
User-Friendly Dual-Dial Interface

User-Friendly Dual-Dial Interface

The host is equipped with tactile control knobs for grip/release interval adjustment and session duration setting. This simple interface makes the device easier for elderly users, family caregivers, and non-professional assistants to operate. The design is especially practical for hemiplegia finger rehabilitation trainer robot gloves in home-care scenarios where complicated digital menus may reduce compliance.
Hygiene Maintenance & Clinical Safe Usage

Hygiene Maintenance & Clinical Safe Usage

The hand robot gloves and main host surface can be cleaned with a soft damp cloth or diluted medical alcohol wipe after use. For patients with severe hand stiffness or high muscle tone, warm compress or gentle massage before training is recommended to improve comfort and reduce resistance during movement.

Partnership & Support Services

Flexible MOQ

Flexible MOQ

Standard models support low-risk market testing from 1 unit, making it easier for distributors, clinics, and rehabilitation equipment buyers to evaluate product performance before larger procurement. OEM/ODM customization can scale to bulk production according to project needs.
Comprehensive Warranty

Comprehensive Warranty

The SL-FR02 is supplied with a 1-year product warranty, supported by spare parts replacement, online troubleshooting, video operation guidance, and multilingual technical communication for distributors and end users.
Resource Center Access

Resource Center Access

We can provide product photos, user manuals, application guidance, CE/FDA-related documents, training materials, and localized marketing support to help distributors promote the product effectively in rehabilitation, home-care, and clinical therapy markets.

Get a Free Quote

Our representative will contact you soon.
Full Name
Company
Work Email
Country
Phone or Whatsapp
Inquiry Type
Message
0/1000

Recommended Products

Ready to Select Rehab Equipment for Your Market?

Tell us about your requirements—target region, clinical application, compliance standards, or volume needs—and we’ll help you identify the right VU rehabilitation solution.

Get a Free Quote

Our representative will contact you soon.
Full Name
Company
Work Email
Country
Phone or Whatsapp
Inquiry Type
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Full Name
Company
Work Email
Country
Phone or Whatsapp
Inquiry Type
Message
0/1000