OEM Automatic Patient Turning Anti-Bedsore Air Mattress

Unit 301 No. 6 Xianghong Road,Torch Hi-Tech Zone Industrial Park,Xiang'an District, Xiamen P.R.China
+86-13365922007 [email protected]

Fully Automatic Patient Turning Anti-Bedsore Air Mattress System for Hospital Bed Care

CE & FDA Certified Automatic Turning Mattress with Smart Pump | 22-Tube Alternating Air Mattress for Pressure Ulcers, Hospital Bed Pressure Relief & Sit-Up Nursing Support

View Compliance Docs
Overview
The VU-AM02 Fully Automatic Patient Turning Anti-Bedsore Air Mattress System for Hospital Bed Care is designed for long-term bedridden care, combining pressure redistribution, automatic posture assistance, and caregiver-friendly operation in one complete solution. It is suitable for hospitals, rehabilitation centers, elderly care homes, nursing institutions, home care suppliers, and medical equipment distributors.
fully automatic patient turning anti bedsore air mattress system for hospital bed care-5
Unlike a basic inflatable bed pad, VU-AM02 integrates a smart air pump, 22 tubular air cells, static/wave mode, left/right turning programs, and gradual sit-up support. It can be positioned as an air mattress for bed sores for patients who require regular pressure relief and posture management.
fully automatic patient turning anti bedsore air mattress system for hospital bed care-6
The mattress measures 200 × 90 cm and is made of thickened durable medical PVC. The pump provides 20–110 mmHg adjustable pressure, 9 / 12 / 25-minute cycle timing, panel lock, alarm indication, and normal/low-pressure status display. For buyers sourcing an air mattress for pressure sores, this model offers both clinical practicality and manufacturer-level supply flexibility.
Fully Automatic Patient Turning Anti-Bedsore Air Mattress System for Hospital Bed Care

Clinical Applications & Care Benefits

Long-Term Bedridden Patient Care

Patients confined to bed for extended periods may face poor circulation, tissue compression, discomfort, and higher risk of pressure injury. VU-AM02 works as an air mattress for pressure ulcers by changing body support areas through controlled tube inflation and deflation.

Alternating Pressure Relief

The mattress uses 22 inflatable tubulars arranged in A/B groups. In wave mode, one group inflates while the other deflates, then the process reverses. This creates a dynamic support surface, making the system a practical alternating air pressure mattress for long-term care environments.

Automatic Turning Assistance

Manual repositioning can be difficult for caregivers, especially in high-frequency nursing scenarios. VU-AM02 supports turn-left, turn-right, and automatic left-right turning. In automatic mode, the system turns one side, holds for about 10 minutes, returns flat, then turns to the other side. This makes it more functional than a standard alternating pressure mattress for bedsores.

Sit-Up Support for Daily Nursing

The sit-up function slowly raises the back section to approximately 45° in about 35 minutes. It supports feeding, communication, reading, and bedside care. Compared with a basic air mattress for bed sores, this design provides broader nursing assistance for long-term patients.

Static Mode for Stable Support

Static mode keeps all air tubes inflated together to form a stable support surface. According to the user manual, fracture patients should use static mode only; wave, turning, and sit-up functions are not suitable unless approved by medical professionals.
Long-Term Bedridden Patient Care
Alternating Pressure Relief
Automatic Turning Assistance
Sit-Up Support for Daily Nursing
Static Mode for Stable Support
01/05

Specifications

Parameter

Specification

Product Name

Fully Automatic Patient Turning Anti-Bedsore Air Mattress System for Hospital Bed Care

Pump Model

VU602

Mattress Model

VU6007

Certification

CE, FDA

Pressure Range

20–110 mmHg

Recommended Pressure

40–60 mmHg after full inflation

Power Consumption

65W

Power Supply

AC220V/50Hz, AC110V/60Hz, AC220V/60Hz

Pump Size

30 × 23.7 × 12.6 cm

Mattress Size

200 × 90 cm

Mattress Structure

22 inflatable air tubulars

Material

Thickened durable medical PVC

Cycle Time

9 / 12 / 25 minutes

Main Functions

Static, wave, turn left, turn right, left-right turning, sit up

Maximum Patient Weight

Not suitable for patients over 135 kg

Working Conditions

5–40℃, RH ≤80%, 70–106 kPa

Pump, Material & User-Centered Design

Smart Pump Control Panel

Smart Pump Control Panel

The white air pump includes alarm indication, low-pressure light, normal status display, pressure setting, cycle time selection, mode buttons, power key, and panel lock. The “+” and “−” buttons allow caregivers to adjust mattress firmness easily. After full inflation, 40–60 mmHg is commonly recommended for comfort and support. This makes VU-AM02 suitable as an air mattress for pressure sores in daily care settings.
22-Tube Pressure Relief Structure

22-Tube Pressure Relief Structure

The mattress is built with 22 independent air tubulars to support alternating pressure and stable static operation. The A/B tube arrangement helps redistribute pressure across the body surface. For buyers searching for an air mattress for pressure ulcers, the tubular design provides a clear and easy-to-demonstrate working principle.
Medical-Grade PVC Surface

Medical-Grade PVC Surface

The blue PVC surface is waterproof, stain-resistant, durable, and easy to clean. It can be wiped with a dry or damp cloth and neutral detergent, supporting repeated use in hospitals, nursing homes, and home care channels. Compared with a general alternating air pressure mattress, this material helps reduce cleaning workload.
Practical Bedside Positioning Design

Practical Bedside Positioning Design

The system supports wave care, turning assistance, and sit-up positioning in one device. For procurement teams comparing a hospital bed pressure mattress, VU-AM02 offers a stronger combination of pressure relief and nursing support, helping facilities improve patient handling efficiency.

Safety, Compliance & Maintenance

Patient Suitability

Patient Suitability

Patients over 135 kg should not use this mattress. Fracture patients should use static mode only. When used as an alternating pressure mattress for bedsores, operation should follow medical advice or caregiver supervision.
Setup Requirements

Setup Requirements

Place the mattress on a clean bed surface without sharp or hard objects. Keep the air inlet near the patient’s feet, connect the quick connector firmly, and ensure the air tube is not pressed or detached. Full inflation usually takes 15–20 minutes.
Cleaning & Storage

Cleaning & Storage

Turn off the pump before cleaning. Do not wash the pump or mattress directly. Wipe with a dry or damp cloth, avoid acid and alkali cleaners, and store in a dry, ventilated, moisture-proof place away from sunlight and heat. Buyers comparing an alternating low air loss mattress will find this PVC tubular system easier to maintain.

Partnership & Support Services

Flexible MOQ & Customization

Flexible MOQ & Customization

Standard stock is available from 1 unit MOQ, suitable for sample testing, distributor evaluation, or small medical facility orders. Customized projects start from 100 units, including logo, packaging, labeling, plug type, carton design, and market-specific documentation. This supports buyers sourcing an alternating air mattress for different regional markets.
Manufacturer Supply Support

Manufacturer Supply Support

As a manufacturer, we support hospitals, rehabilitation equipment importers, elderly care suppliers, and home care distributors with product information, operation guidance, and stable supply service. For buyers comparing a hospital bed pressure mattress or alternating low air loss mattress, VU-AM02 offers practical functions and clear product positioning.
Warranty & Online Technical Support

Warranty & Online Technical Support

Each unit includes 1-year warranty and online technical support for installation, operation, troubleshooting, and after-sales communication. This helps partners maintain long-term service continuity for the alternating air mattress category and related alternating low air loss mattress procurement needs.

Get a Free Quote

Our representative will contact you soon.
Full Name
Company
Work Email
Country
Phone or Whatsapp
Inquiry Type
Message
0/1000

Recommended Products

Ready to Select Rehab Equipment for Your Market?

Tell us about your requirements—target region, clinical application, compliance standards, or volume needs—and we’ll help you identify the right VU rehabilitation solution.

Get a Free Quote

Our representative will contact you soon.
Full Name
Company
Work Email
Country
Phone or Whatsapp
Inquiry Type
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Full Name
Company
Work Email
Country
Phone or Whatsapp
Inquiry Type
Message
0/1000